This is a purely informative rendering of an RFC that includes verified errata. This rendering may not be used as a reference.

The following 'Verified' errata have been incorporated in this document: EID 8041


Internet Engineering Task Force (IETF)                         M. Miller
Request for Comments: 9239
Obsoletes: 4329                                                M. Borins
Category: Informational                                           GitHub
ISSN: 2070-1721                                                M. Bynens
                                                                  Google
                                                               B. Farias
                                                                May 2022

                   Updates to ECMAScript Media Types

Abstract

   This document describes the registration of media types for the
   ECMAScript and JavaScript programming languages and conformance
   requirements for implementations of these types.  This document
   obsoletes RFC 4329 ("Scripting Media Types)", replacing the previous
   registrations with information and requirements aligned with common
   usage and implementation experiences.

IESG Note

   This document records the relationship between the work of Ecma
   International's Technical Committee 39 and the media types used to
   identify relevant payloads.

   That relationship was developed outside of the IETF and as a result
   is unfortunately not aligned with the best practices of BCP 13.
   Consequently, consensus exists in the IETF to document the
   relationship and update the relevant IANA registrations for those
   media types, but this is not an IETF endorsement of the media types
   chosen for this work.

Status of This Memo

   This document is not an Internet Standards Track specification; it is
   published for informational purposes.

   This document is a product of the Internet Engineering Task Force
   (IETF).  It represents the consensus of the IETF community.  It has
   received public review and has been approved for publication by the
   Internet Engineering Steering Group (IESG).  Not all documents
   approved by the IESG are candidates for any level of Internet
   Standard; see Section 2 of RFC 7841.

   Information about the current status of this document, any errata,
   and how to provide feedback on it may be obtained at
   https://www.rfc-editor.org/info/rfc9239.

Copyright Notice

   Copyright (c) 2022 IETF Trust and the persons identified as the
   document authors.  All rights reserved.

   This document is subject to BCP 78 and the IETF Trust's Legal
   Provisions Relating to IETF Documents
   (https://trustee.ietf.org/license-info) in effect on the date of
   publication of this document.  Please review these documents
   carefully, as they describe your rights and restrictions with respect
   to this document.  Code Components extracted from this document must
   include Revised BSD License text as described in Section 4.e of the
   Trust Legal Provisions and are provided without warranty as described
   in the Revised BSD License.

Table of Contents

   1.  Introduction
     1.1.  Terminology
   2.  Compatibility
   3.  Modules
   4.  Encoding
     4.1.  Charset Parameter
     4.2.  Character Encoding Scheme Detection
     4.3.  Character Encoding Scheme Error Handling
   5.  Security Considerations
   6.  IANA Considerations
     6.1.  Common JavaScript Media Types
       6.1.1.  text/javascript
     6.2.  Historic JavaScript Media Types
       6.2.1.  text/ecmascript
   7.  References
     7.1.  Normative References
     7.2.  Informative References
   Appendix A.  Changes from RFC 4329
   Acknowledgements
   Authors' Addresses

1.  Introduction

   This memo describes media types for the JavaScript and ECMAScript
   programming languages.  Refer to the sections "Introduction" and
   "Overview" in [ECMA-262] for background information on these
   languages.  This document updates the descriptions and registrations
   for these media types to reflect existing usage on the Internet, and
   it provides up-to-date security considerations.

   This document replaces the media type registrations in [RFC4329] and
   updates the requirements for implementations using those media types
   defined in [RFC4329] based on current existing practices.  As a
   consequence, this document obsoletes [RFC4329].

1.1.  Terminology

   The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
   "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
   "OPTIONAL" in this document are to be interpreted as described in
   BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
   capitals, as shown here.

2.  Compatibility

   This document defines equivalent processing requirements for the
   various script media types.  The most widely supported media type in
   use is text/javascript; all others are considered historical and
   obsolete aliases of text/javascript.

   The types defined in this document are applicable to scripts written
   in [ECMA-262].  New editions of [ECMA-262] are subjected to strong
   obligations of backward compatibility, imposed by the standardization
   process of Ecma International's Technical Committee 39 (TC39).  As a
   result, JavaScript code based on an earlier edition is generally
   compatible with a JavaScript engine adhering to a later edition.  The
   few exceptions to this are documented in [ECMA-262] in the section
   "Additions and Changes That Introduce Incompatibilities with Prior
   Editions".  JavaScript developers commonly use feature detection to
   ensure that modern JavaScript features are only used when available
   in the current environment.  Later editions of [ECMA-262] are not
   directly addressed in this document, although it is expected that
   implementations will behave as if applicability were extended to
   them.  This document does not address other extensions to [ECMA-262]
   or scripts written in other languages.

   This document may be updated to take other content into account.
   Updates of this document may introduce new optional parameters;
   implementations must consider the impact of such an update.

   This document does not define how fragment identifiers in resource
   identifiers [RFC3986] [RFC3987] for documents labeled with one of the
   media types defined in this document are resolved.  An update of this
   document may define processing of fragment identifiers.

   Note that this use of the "text" media type tree willfully does not
   align with its original intent per [RFC2045].  The reason for this is
   historical.  [RFC4329] registered both the text/* and application/*
   types, marking the text/* types obsolete.  This was done to encourage
   people toward application/*, matching the guidance in [RFC4288], the
   predecessor to [RFC6838].  Since then, however, the industry widely
   adopted text/* anyway.  The definitions in this document reflect the
   current state of implementation across the JavaScript ecosystem, in
   web browsers and other environments such as Node.js alike, in order
   to guarantee backward compatibility with existing applications as
   much as possible.  Future registrations should not view this as a
   repeatable precedent.

3.  Modules

   In order to formalize support for modular programs, [ECMA-262]
   (starting with the 6th Edition) defines two top-level goal symbols
   (or roots to the abstract syntax tree) for the ECMAScript grammar:
   Module and Script.  The Script goal represents the original structure
   where the code executes in the global scope, while the Module goal
   represents the module system built into ECMAScript starting with the
   6th Edition.  See the section "ECMAScript Language: Scripts and
   Modules" in [ECMA-262] for details.

   This separation means that (in the absence of additional information)
   there are two possible interpretations for any given ECMAScript
   source text.

   Ecma International's Technical Committee 39 (TC39), the standards
   body in charge of ECMAScript, has determined that media types are
   outside of their scope of work [TC39-MIME-ISSUE].

   It is not possible to fully determine if a source text of ECMAScript
   is meant to be parsed using the Module or Script grammar goals based
   upon content or media type alone.  Therefore, as permitted by the
   media types in this document, scripting environments use out-of-band
   information in order to determine what goal should be used.  Some
   scripting environments have chosen to adopt the file extension of
   .mjs for this purpose.

4.  Encoding

   Refer to [RFC6365] for a discussion of terminology used in this
   section.  Source text (as defined in the section "Source Text" in
   [ECMA-262]) can be binary source text.  Binary source text is a
   textual data object that represents source text encoded using a
   character encoding scheme.  A textual data object is a whole text
   protocol message or a whole text document, or a part of it, that is
   treated separately for purposes of external storage and retrieval.
   An implementation's internal representation of source text is not
   considered binary source text.

   Implementations need to determine a character encoding scheme in
   order to decode binary source text to source text.  The media types
   defined in this document allow an optional charset parameter to
   explicitly specify the character encoding scheme used to encode the
   source text.

   In order to ensure interoperability and align with widespread
   implementation practices, the charset parameter is optional rather
   than required, despite the recommendation in BCP 13 [RFC6838] for
   text/* types.

   How implementations determine the character encoding scheme can be
   subject to processing rules that are out of the scope of this
   document.  For example, transport protocols can require that a
   specific character encoding scheme is to be assumed if the optional
   charset parameter is not specified, or they can require that the
   charset parameter is used in certain cases.  Such requirements are
   not defined by this document.

   Implementations that support binary source text MUST support binary
   source text encoded using the UTF-8 [RFC3629] character encoding
   scheme.  Module goal sources MUST be encoded as UTF-8; all other
   encodings will fail.  Script goal sources SHOULD be encoded as UTF-8; 
EID 8041 (Verified) is as follows:

Section: 4

Original Text:

Source goal sources SHOULD be encoded as UTF-8

Corrected Text:

Script goal sources SHOULD be encoded as UTF-8
Notes:
Section 3 says there are only two goals: Module and Script. That "Source goal" is a typo and should read "Script goal".
other character encoding schemes MAY be supported but are discouraged. Whether U+FEFF is processed as a Byte Order Mark (BOM) signature or not depends on the host environment and is not defined by this document. 4.1. Charset Parameter The charset parameter provides a means to specify the character encoding scheme of binary source text. If present, the value of the charset parameter MUST be a registered charset [CHARSETS] and is considered valid if it matches the mime-charset production defined in Section 2.3 of [RFC2978]. The charset parameter is only used when processing a Script goal source; Module goal sources MUST always be processed as UTF-8. 4.2. Character Encoding Scheme Detection It is possible that implementations cannot interoperably determine a single character encoding scheme simply by complying with all requirements of the applicable specifications. To foster interoperability in such cases, the following algorithm is defined. Implementations apply this algorithm until a single character encoding scheme is determined. 1. If the binary source text is not already determined to be using a Module goal and starts with a Unicode encoding form signature, the signature determines the encoding. The following octet sequences, at the very beginning of the binary source text, are considered with their corresponding character encoding schemes: +==================+==========+ | Leading sequence | Encoding | +==================+==========+ | EF BB BF | UTF-8 | +------------------+----------+ | FF FE | UTF-16LE | +------------------+----------+ | FE FF | UTF-16BE | +------------------+----------+ Table 1 Implementations of this step MUST use these octet sequences to determine the character encoding scheme, even if the determined scheme is not supported. If this step determines the character encoding scheme, the octet sequence representing the Unicode encoding form signature MUST be ignored when decoding the binary source text. 2. Else, if a charset parameter is specified and its value is valid and supported by the implementation, the value determines the character encoding scheme. 3. Else, the character encoding scheme is assumed to be UTF-8. If the character encoding scheme is determined to be UTF-8 through any means other than step 1 as defined above and the binary source text starts with the octet sequence EF BB BF, the octet sequence is ignored when decoding the binary source text. 4.3. Character Encoding Scheme Error Handling Binary source text that is not properly encoded for the determined character encoding can pose a security risk, as discussed in Section 5. That said, because of the varied and complex environments scripts are executed in, most of the error handling specifics are left to the processors. The following are broad guidelines that processors follow. If binary source text is determined to have been encoded using a certain character encoding scheme that the implementation is unable to process, implementations can consider the resource unsupported (i.e., do not decode the binary source text using a different character encoding scheme). Binary source text can be determined to have been encoded using a certain character encoding scheme but contain octet sequences that are not valid according to that scheme. Implementations can substitute those invalid sequences with the replacement character U+FFFD (properly encoded for the scheme) or stop processing altogether. 5. Security Considerations Refer to [RFC3552] for a discussion of terminology used in this section. Examples in this section and discussions of interactions of host environments with scripts, modules, and extensions to [ECMA-262] are to be understood as non-exhaustive and of a purely illustrative nature. The programming language defined in [ECMA-262] is not intended to be computationally self-sufficient; rather, it is expected that the computational environment provides facilities to programs to enable specific functionality. Such facilities constitute unknown factors and are thus not defined by this document. Derived programming languages are permitted to include additional functionality that is not described in [ECMA-262]; such functionality constitutes an unknown factor and is thus not defined by this document. In particular, extensions to [ECMA-262] defined for the JavaScript programming language are not discussed in this document. Uncontrolled execution of scripts can be exceedingly dangerous. Implementations that execute scripts MUST give consideration to their application's threat models and those of the individual features they implement; in particular, they MUST ensure that untrusted content is not executed in an unprotected environment. Module scripts in ECMAScript can request the fetching and processing of additional scripts; this is called "importing". Implementations that support modules need to process imported sources in the same way as scripts. See the section "ECMAScript Language: Scripts and Modules" in [ECMA-262] for details. Further, there may be additional privacy and security concerns, depending on the location(s) the original script and its imported modules are obtained from. For instance, a script obtained from "host-a.example" could request to import a script from "host-b.example", which could expose information about the executing environment (e.g., IP address) to "host- b.example". Specifications for host environment facilities and for derived programming languages should include security considerations. If an implementation supports such facilities, the respective security considerations apply. In particular, if scripts can be referenced from or included in specific document formats, the considerations for the embedding or referencing document format apply. For example, scripts embedded in application/xhtml+xml [RFC3236] documents could be enabled through the host environment to manipulate the document instance, which could cause the retrieval of remote resources; security considerations regarding retrieval of remote resources of the embedding document would apply in this case. This circumstance can further be used to make information that is normally only available to the script also available to a web server by encoding the information in the resource identifier of the resource, which can further enable eavesdropping attacks. Implementation of such facilities is subject to the security considerations of the host environment, as discussed above. The programming language defined in [ECMA-262] does include facilities to loop, cause computationally complex operations, or consume large amounts of memory; this includes, but is not limited to, facilities that allow dynamically generated source text to be executed (e.g., the eval() function); uncontrolled execution of such features can cause denial of service, which implementations MUST protect against. With the addition of SharedArrayBuffer objects in ECMAScript version 8, it could be possible to implement a high-resolution timer, which could lead to certain types of timing and side-channel attacks (e.g., [SPECTRE]). Implementations can take steps to mitigate this concern, such as disabling or removing support for SharedArrayBuffer objects, or can take additional steps to ensure that this shared memory is only accessible between execution contexts that have some form of mutual trust. A host environment can provide facilities to access external input. Scripts that pass such input to the eval() function or similar language features can be vulnerable to code injection attacks. Scripts are expected to protect against such attacks. A host environment can provide facilities to output computed results in a user-visible manner. For example, host environments supporting a graphical user interface can provide facilities that enable scripts to present certain messages to the user. Implementations MUST take steps to avoid confusion of the origin of such messages. In general, the security considerations for the host environment apply in such a case as discussed above. Implementations are required to support the UTF-8 character encoding scheme; the security considerations of [RFC3629] apply. Additional character encoding schemes may be supported; support for such schemes is subject to the security considerations of those schemes. Source text is expected to be in Unicode Normalization Form C. Scripts and implementations MUST consider security implications of unnormalized source text and data. For a detailed discussion of such implications, refer to the security considerations in [RFC3629]. Scripts can be executed in an environment that is vulnerable to code injection attacks. For example, a Common Gateway Interface (CGI) script [RFC3875] echoing user input could allow the inclusion of untrusted scripts that could be executed in an otherwise trusted environment. This threat scenario is subject to security considerations that are out of the scope of this document. The "data" resource identifier scheme [RFC2397], in combination with the types defined in this document, could be used to cause execution of untrusted scripts through the inclusion of untrusted resource identifiers in otherwise trusted content. Security considerations of [RFC2397] apply. Implementations can fail to implement a specific security model or other means to prevent possibly dangerous operations. Such failure could possibly be exploited to gain unauthorized access to a system or sensitive information; such failure constitutes an unknown factor and is thus not defined by this document. 6. IANA Considerations The media type registrations herein are divided into two major categories: (1) the sole media type "text/javascript", which is now in common usage and (2) all of the media types that are obsolete (i.e., "application/ecmascript", "application/javascript", "application/x-ecmascript", "application/x-javascript", "text/ ecmascript", "text/javascript1.0", "text/javascript1.1", "text/ javascript1.2", "text/javascript1.3", "text/javascript1.4", "text/ javascript1.5", "text/jscript", "text/livescript", and "text/ x-ecmascript"). For both categories, the "Published specification" entry for the media types is updated to reference [ECMA-262]. In addition, a new file extension of .mjs has been added to the list of file extensions with the restriction that contents should be parsed using the Module goal. Finally, the [HTML] specification uses "text/javascript" as the default media type of ECMAScript when preparing script tags; therefore, "text/javascript" intended usage has been moved from OBSOLETE to COMMON. These changes have been reflected in the IANA "Media Types" registry in accordance with [RFC6838]. All registrations will point to this document as the reference. The outdated note stating that the "text/ javascript" media type has been "OBSOLETED in favor of application/ javascript" has been removed. The outdated note stating that the "text/ecmascript" media type has been "OBSOLETED in favor of application/ecmascript" has been removed. IANA has added the note "OBSOLETED in favor of text/javascript" to all registrations except "text/javascript"; that is, this note has been added to the "text/ ecmascript", "application/javascript", and "application/ecmascript" registrations. Four of the legacy media types in this document have a subtype starting with the "x-" prefix: * application/x-ecmascript * application/x-javascript * text/x-ecmascript * text/x-javascript Note that these are grandfathered media types registered as per Appendix A of [RFC6838]. These registrations predate BCP 178 [RFC6648], which they violate, and are only included in this document for backward compatibility. 6.1. Common JavaScript Media Types 6.1.1. text/javascript Type name: text Subtype name: javascript Required parameters: N/A Optional parameters: charset. See Section 4.1 of RFC 9239. Encoding considerations: Binary Security considerations: See Section 5 of RFC 9239. Interoperability considerations: It is expected that implementations will behave as if this registration applies to later editions of [ECMA-262], and its published specification references may be updated accordingly from time to time. Although this expectation is unusual among media type registrations, it matches widespread industry conventions. See Section 2 of RFC 9239. Published specification: [ECMA-262] Applications that use this media type: Script interpreters as discussed in RFC 9239. Additional information: Deprecated alias names for this type: application/javascript, application/x-javascript, text/javascript1.0, text/ javascript1.1, text/javascript1.2, text/javascript1.3, text/ javascript1.4, text/javascript1.5, text/jscript, text/ livescript Magic number(s): N/A File extension(s): .js, .mjs Macintosh File Type Code(s): TEXT Person & email address to contact for further information: See the Authors' Addresses sections of RFC 9239 and [RFC4329]. Intended usage: COMMON Restrictions on usage: The .mjs file extension signals that the file represents a JavaScript module. Execution environments that rely on file extensions to determine how to process inputs parse .mjs files using the Module grammar of [ECMA-262]. Author: See the Authors' Addresses sections of RFC 9239 and [RFC4329]. Change controller: IESG <iesg@ietf.org> 6.2. Historic JavaScript Media Types The following media types and legacy aliases are added or updated for historical purposes. All herein have an intended usage of OBSOLETE and are not expected to be in use with modern implementations. 6.2.1. text/ecmascript Type name: text Subtype name: ecmascript Required parameters: N/A Optional parameters: charset. See Section 4.1 of RFC 9239. Encoding considerations: Binary Security considerations: See Section 5 of RFC 9239. Interoperability considerations: It is expected that implementations will behave as if this registration applies to later editions of [ECMA-262], and its published specification references may be updated accordingly from time to time. Although this expectation is unusual among media type registrations, it matches widespread industry conventions. See Section 2 of RFC 9239. Published specification: [ECMA-262] Applications that use this media type: Script interpreters as discussed in RFC 9239. Additional information: Deprecated alias names for this type: application/ecmascript, application/x-ecmascript, text/x-ecmascript Magic number(s): N/A File extension(s): .es, .mjs Macintosh File Type Code(s): TEXT Person & email address to contact for further information: See the Authors' Addresses sections of RFC 9239 and [RFC4329]. Intended usage: OBSOLETE Restrictions on usage: This media type is obsolete; current implementations should use text/javascript as the only JavaScript/ ECMAScript media type. The .mjs file extension signals that the file represents a JavaScript module. Execution environments that rely on file extensions to determine how to process inputs parse .mjs files using the Module grammar of [ECMA-262]. Author: See the Authors' Addresses sections of RFC 9239 and [RFC4329]. Change controller: IESG <iesg@ietf.org> 7. References 7.1. Normative References [CHARSETS] IANA, "Character Sets", <https://www.iana.org/assignments/character-sets>. [ECMA-262] Ecma International, "ECMA-262 12th Edition, June 2021. ECMAScript 2021 language specification", June 2021, <https://262.ecma-international.org/12.0/>. [RFC2045] Freed, N. and N. Borenstein, "Multipurpose Internet Mail Extensions (MIME) Part One: Format of Internet Message Bodies", RFC 2045, DOI 10.17487/RFC2045, November 1996, <https://www.rfc-editor.org/info/rfc2045>. [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", BCP 14, RFC 2119, DOI 10.17487/RFC2119, March 1997, <https://www.rfc-editor.org/info/rfc2119>. [RFC2397] Masinter, L., "The "data" URL scheme", RFC 2397, DOI 10.17487/RFC2397, August 1998, <https://www.rfc-editor.org/info/rfc2397>. [RFC2978] Freed, N. and J. Postel, "IANA Charset Registration Procedures", BCP 19, RFC 2978, DOI 10.17487/RFC2978, October 2000, <https://www.rfc-editor.org/info/rfc2978>. [RFC3552] Rescorla, E. and B. Korver, "Guidelines for Writing RFC Text on Security Considerations", BCP 72, RFC 3552, DOI 10.17487/RFC3552, July 2003, <https://www.rfc-editor.org/info/rfc3552>. [RFC3629] Yergeau, F., "UTF-8, a transformation format of ISO 10646", STD 63, RFC 3629, DOI 10.17487/RFC3629, November 2003, <https://www.rfc-editor.org/info/rfc3629>. [RFC4288] Freed, N. and J. Klensin, "Media Type Specifications and Registration Procedures", RFC 4288, DOI 10.17487/RFC4288, December 2005, <https://www.rfc-editor.org/info/rfc4288>. [RFC4329] Hoehrmann, B., "Scripting Media Types", RFC 4329, DOI 10.17487/RFC4329, April 2006, <https://www.rfc-editor.org/info/rfc4329>. [RFC6365] Hoffman, P. and J. Klensin, "Terminology Used in Internationalization in the IETF", BCP 166, RFC 6365, DOI 10.17487/RFC6365, September 2011, <https://www.rfc-editor.org/info/rfc6365>. [RFC6648] Saint-Andre, P., Crocker, D., and M. Nottingham, "Deprecating the "X-" Prefix and Similar Constructs in Application Protocols", BCP 178, RFC 6648, DOI 10.17487/RFC6648, June 2012, <https://www.rfc-editor.org/info/rfc6648>. [RFC6838] Freed, N., Klensin, J., and T. Hansen, "Media Type Specifications and Registration Procedures", BCP 13, RFC 6838, DOI 10.17487/RFC6838, January 2013, <https://www.rfc-editor.org/info/rfc6838>. [RFC8174] Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC 2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174, May 2017, <https://www.rfc-editor.org/info/rfc8174>. 7.2. Informative References [HTML] WHATWG, "HTML Living Standard", May 2022, <https://html.spec.whatwg.org/multipage/ scripting.html#prepare-a-script>. [RFC3236] Baker, M. and P. Stark, "The 'application/xhtml+xml' Media Type", RFC 3236, DOI 10.17487/RFC3236, January 2002, <https://www.rfc-editor.org/info/rfc3236>. [RFC3875] Robinson, D. and K. Coar, "The Common Gateway Interface (CGI) Version 1.1", RFC 3875, DOI 10.17487/RFC3875, October 2004, <https://www.rfc-editor.org/info/rfc3875>. [RFC3986] Berners-Lee, T., Fielding, R., and L. Masinter, "Uniform Resource Identifier (URI): Generic Syntax", STD 66, RFC 3986, DOI 10.17487/RFC3986, January 2005, <https://www.rfc-editor.org/info/rfc3986>. [RFC3987] Duerst, M. and M. Suignard, "Internationalized Resource Identifiers (IRIs)", RFC 3987, DOI 10.17487/RFC3987, January 2005, <https://www.rfc-editor.org/info/rfc3987>. [SPECTRE] Kocher, P., Genkin, D., Gruss, D., Haas, W., Hamburg, M., Lipp, M., Mangard, S., Prescher, T., Schwarz, M., and Y. Yarom, "Spectre Attacks: Exploiting Speculative Execution", DOI 10.48550/arXiv.1801.01203, January 2018, <https://arxiv.org/abs/1801.01203>. [TC39-MIME-ISSUE] TC39, "Add 'application/javascript+module' mime to remove ambiguity", Wayback Machine archive, August 2017, <https:/ /web.archive.org/web/20170814193912/https://github.com/ tc39/ecma262/issues/322>. Appendix A. Changes from RFC 4329 * Added a section discussing ECMAScript modules and the impact on processing. * Updated the Security Considerations section to discuss concerns associated with ECMAScript modules and SharedArrayBuffers. * Updated the character encoding scheme detection to remove normative guidance on its use, to better reflect operational reality. * Changed the intended usage of the media type "text/javascript" from OBSOLETE to COMMON. * Changed the intended usage for all other script media types to obsolete. * Updated various references where the original has been obsoleted. * Updated references to ECMA-262 to match the version at the time of publication. Acknowledgements This work builds upon its antecedent document, authored by Björn Höhrmann. The authors would like to thank Adam Roach, Alexey Melnikov, Allen Wirfs-Brock, Anne van Kesteren, Ben Campbell, Benjamin Kaduk, Éric Vyncke, Francesca Palombini, James Snell, Kirsty Paine, Mark Nottingham, Murray Kucherawy, Ned Freed, Robert Sparks, and Suresh Krishnan for their guidance and feedback throughout this process. Authors' Addresses Matthew A. Miller Email: linuxwolf+ietf@outer-planes.net Myles Borins GitHub Email: mylesborins@github.com Mathias Bynens Google Email: mths@google.com Bradley Farias Email: bradley.meck@gmail.com