<?xml version="1.0" encoding="utf-8"?>
<?xml-model href="rfc7991bis.rnc"?>  <!-- Required for schema
      validation and schema-aware editing --> 
<!-- <?xml-stylesheet type="text/xsl" href="rfc2629.xslt" ?> --> 
<!-- This third-party XSLT can be enabled for direct transformations
in XML processors, including most browsers --> 

<!DOCTYPE rfc [
  <!ENTITY filename "draft-ietf-bess-evpn-bfd-13">
  <!ENTITY nbsp    "&#160;">
  <!ENTITY zwsp   "&#8203;">
  <!ENTITY nbhy   "&#8209;">
  <!ENTITY wj     "&#8288;">
]>
<!-- If further character entities are required then they should be
added to the DOCTYPE above. Use of an external entity file is not
recommended. --> 
<?rfc strict="yes" ?>
<!-- give errors regarding ID-nits and DTD validation -->
<!-- control the table of contents (ToC) -->
<?rfc toc="yes"?>

<rfc
  xmlns:xi="http://www.w3.org/2001/XInclude"
  category="std"
  docName="&filename;"
  ipr="trust200902"
  updates=""
  submissionType="IETF"
  xml:lang="en"
  version="3">
<!-- 
    * docName should be the name of your draft * category should be
    one of std, bcp, info, exp, historic * ipr should be one of
    trust200902, noModificationTrust200902, noDerivativesTrust200902,
    pre5378Trust200902 * updates can be an RFC number as NNNN *
    obsoletes can be an RFC number as NNNN
-->


<!-- ____________________FRONT_MATTER____________________ -->
<front>
  <title>EVPN Network Layer Fault Management</title>

   <seriesInfo name="Internet-Draft"
               value="&filename;"/>
   
   <author fullname="Vengada Prasad Govindan" initials="V."
           surname="Govindan">
     <organization>Cisco Systems</organization>
     <address>
       <email>venggovi@cisco.com</email>
     </address>
   </author>
   
   <author fullname="Ali Sajassi" initials="A."
           surname="Sajassi">
     <organization>Cisco Systems</organization>
     <address>
       <postal>
         <street>170 West Tasman Drive</street>
         <city>San Jose</city>
         <region>CA</region>
         <code>95134</code>
         <country>US</country>
       </postal>        
       <email>sajassi@cisco.com</email>
     </address>
   </author>

   <author fullname="Mudigonda Mallik" initials="M."
           surname="Mudigonda">
     <organization>Celestica Inc.</organization>
     <address>
       <email>mallik.mj@celestica.com</email>
     </address>
   </author>

   
   <author fullname="Gregory Mirsky" initials="G."
           surname="Mirsky">
     <organization>Independent</organization>
     <address>
       <email>gregmirsky@gmail.com</email>
     </address>
   </author>

   <author fullname="Donald E. Eastlake 3rd" initials="D."
           surname="Eastlake">
     <organization>Independent</organization>
     <address>
       <postal>
         <street>2386 Panoramic Circle</street>
         <city>Apopka</city>
         <region>FL</region>
         <code>32703</code>
         <country>US</country>
       </postal>        
       <email>d3e3e3@gmail.com</email>
     </address>
   </author>

   <date year="2026" month="3" day="27"/>

   <area>Routing</area>
   <workgroup>BESS Working Group</workgroup>
   <!-- "Internet Engineering Task Force" is fine for individual
        submissions.  If this element is not present, the default is
        "Network Working Group", which is used by the RFC Editor as a
        nod to the history of the RFC Series. --> 

   <keyword></keyword>
   <!-- Multiple keywords are allowed.  Keywords are incorporated
        into HTML output files for use by search engines. --> 

   <abstract>
    <t>This document specifies proactive, in-band network layer OAM
    (RFC 9062) mechanisms to detect loss of continuity faults that
    affect unicast and multi-destination paths (used by Broadcast,
    Unknown Unicast, and Multicast traffic) in an Ethernet VPN (EVPN,
    RFC 7432bis) network.  The mechanisms specified in this document
    use the widely adopted Bidirectional Forwarding Detection (RFC
    5880) protocol.</t>
   </abstract>

</front>


<!-- ____________________MIDDLE_MATTER____________________ -->
<middle>
    
<section>  <!-- 1. -->
  <name>Introduction</name>

    <t><xref target="RFC9062"/> outlines the OAM requirements of
    Ethernet VPN (EVPN) <xref target="rfc7432bis"/>.  This document
    specifies mechanisms for proactive fault detection at the network
    (overlay) layer of EVPN, that is to say between Provider Edge (PE)
    nodes, as shown in <xref target="OAMlayers"/> taken from <xref
    target="RFC9062"/> and described in Section 2.3 of <xref
    target="RFC9062"/>. The mechanisms specified in this document use
    the widely adopted Bidirectional Forwarding Detection (BFD, <xref
    target="RFC5880"/> <xref target="RFC5881"/> <xref
    target="RFC5882"/> <xref target="RFC5883"/> <xref
    target="RFC5884"/>) protocol, which is a lightweight in-band
    protocol using fixed length messages suitable for implementation
    in hardware. All these mechanisms are applied as active in-band
    OAM methods, i.e., specially constructed OAM packets traverse the
    same set of links and interfaces receiving the same forwarding
    behavior as the monitored EVPN flow. EVPN service restoration
    mechanisms (redundancy and recovery/convergence) are the most
    logical clients, in the <xref target="RFC5882"/> sense, for BFD
    sessions specified herein.</t>

<figure anchor="OAMlayers">
<name>OAM Layering</name>
<artwork>
        +---+                               +---+
+--+    |   |    +---+    +---+    +---+    |   |    +--+
|CE|----|PE |----| P |----| P |----| P |----|PE |----|CE|
+--+    |   |    +---+    +---+    +---+    |   |    +--+
        +---+                               +---+
  o-------o----------- Service OAM -----------o-------o
        
          o----------- Network OAM -----------o
        
          o--------o--------o--------o--------o  Transport OAM
        
   o----o   o----o   o----o   o----o   o----o   o----o  Link OAM
</artwork>
</figure>

    <t> EVPN Network Layer OAM monitors connectivity between peer 
    Bridge-table instances. In the case of VLAN-based and VLAN Bundle service
    interfaces, this is equivalent to MAC-VRF-to-MAC-VRF connectivity because 
    each MAC-VRF contains just one BT which is identified by the application
    label/VNI in the DP. In the case of VLAN-aware Bundle service interface:</t>
    <ul>
     <li> Each MAC-VRF contains multiple BTs. </li>
     <li> In EVPN-VxLAN each BT is still identified by its own VNI in the DP. </li>
     <li> In EVPN-MPLS a BT can be identified in the DP by its own application
     label, or by the combination of the application label and the 
     "normalized VLAN tag" in the customer Ethernet frame. This document
     does not cover the case where the BT is identified using the VLAN tag but
     relies on the identification of the BT solely by using the application
     label.</li>
    </ul>

    <t>EVPN fault detection mechanisms need to consider unicast
    traffic separately from Broadcast, Unknown Unicast, and Multicast
    (BUM) traffic since they map to different Forwarding Equivalency
    Classes (FECs) in EVPN so such traffic may follow different
    paths. Hence this document specifies different continuity fault
    detection mechanisms, depending on the type of traffic and the
    type of tunnel used, as follows (see also Section 2.3 of <xref
    target="RFC9062"/>):</t>

    <ul>
      <li>Using BFD <xref target="RFC5880"/> for unicast traffic and
      BUM traffic via Point to Point (P2P) and Multipoint to Point
      (MP2P) tunnels.</li>

      <li>Using BFD Multipoint <xref target="RFC8562"/> or BFD
      Multipoint Active Tails <xref target="RFC8563"/> <xref
      target="ietf-mpls-p2mp-bfd"/> for BUM traffic via a Point to
      Multipoint (P2MP) tunnels.</li>
    </ul>
    

    <t>Packet loss and packet delay measurement are out of scope for
    this document. See <xref target="ietf-bmwg-evpntest"/> for EVPN
    benchmarking guidance.</t>

    <t>At least three types of mis-programming of the application label can
     occur:</t>
      <ul>
      <li>It is not known in the data plane of the egress EVPN PE.</li>
      <li>It is known and is programmed with action "swap and forward". </li>
      <li> It is known and is programmed as "pop and forward" but to a 
      different BT. </li> </ul>

    <t> While the mechanisms of this document can cover the first two cases,
    the last case is not be covered by this document since that may require
    changes to rules for association of a received BFD packets as specified in
    <xref target="RFC5880"/> especially when EVPN encapsulated BFD packets
    are handled by OAM processors in off-the-shelf forwarding hardware.</t>

    <t> The primary motivation of using BFD for detecting liveness is to
    report failures to an operator who may initiate corrective action. This
    document does not provide any mechanisms for repairing faults. </t>

</section>
<section>
  <name>Terminology</name>

    <t>The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL
    NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED",
    "MAY", and "OPTIONAL" in this document are to be interpreted as
    described in BCP 14 <xref target="RFC2119"/> <xref
    target="RFC8174"/> when, and only when, they appear in all
    capitals, as shown here.</t>

    <t>The following acronyms are used in this document.</t>

<dl newline="false">
<dt>BFD</dt><dd>-  Bidirectional Forwarding Detection <xref
target="RFC5880"/></dd> 
<dt>BUM</dt><dd>-  Broadcast, Unknown Unicast, and Multicast</dd>
<dt>CC</dt><dd>-  Continuity Check</dd>
<dt>CE</dt><dd>-  Customer Edge</dd>
<dt>EVI</dt><dd>-  EVPN Instance</dd>
<dt>EVPN</dt><dd>-  Ethernet VPN <xref target="rfc7432bis"/></dd>
<dt>FEC</dt><dd>-  Forwarding Equivalency Class</dd>
<dt>LSM</dt><dd>-  Label Switched Multicast (P2MP)</dd>
<dt>LSP</dt><dd>-  Label Switched Path</dd>
<dt>MP2MP</dt><dd>-  Multipoint to Multipoint</dd>
<dt>MP2P</dt><dd>-  Multipoint to Point</dd>
<dt>MPLS</dt><dd>- MultiProtocol Label Switching</dd>
<dt>OAM</dt><dd>-  Operations, Administration, and Maintenance</dd>
<dt>P2MP</dt><dd>-  Point to Multipoint (LSM)</dd>
<dt>P2P</dt><dd>-  Point to Point</dd>
<dt>PE</dt><dd>-  Provider Edge</dd>
<dt>VXLAN</dt><dd>-  Virtual eXtensible Local Area Network <xref
target="RFC7348"/></dd> 
</dl>

</section>

<section>  <!-- 2. -->
  <name>Scope of this Document</name>

  <t>This document specifies BFD-based mechanisms for proactive fault
  detection at the Network Layer (as specified in Section 2.3 of <xref
  target="RFC9062"/>) for MPLS based EVPN (as specified in <xref
  target="rfc7432bis"/>) and also for EVPN using VXLAN encapsulation
  <xref target="RFC8365"/>. Specifically, this document covers the
  following:</t>

  <ul>
    <li>Unicast traffic using Point to Point (P2P) and
    Multipoint to Point (MP2P) tunnels.</li>

    <li>BUM traffic using ingress replication via Point to Point (P2P)
    and Multipoint to Point (MP2P) tunnels.</li>

    <li>BUM traffic using Point to Multipoint (P2MP) tunnels (Label
    Switched Multicast (LSM)).</li>

    <li>MPLS and VXLAN encapsulation.</li>
  </ul>

  <t>This document does not discuss BFD mechanisms for:</t>

  <ul>
    <li>The PBB-EVPN <xref target="RFC7623"/> EVPN variant. It is
    intended to address this in a future document.</li>

    <li>Monitoring EVPN E-Tree services <xref target="RFC8317"/> is outside
    the scope of this document since lack of connectivity between two BTs that
    have just Leaf ACs would have no impact on the EVPN BFD session.</li>

    <li>EVPN using other encapsulations such as NVGRE or MPLS over GRE
    (see Section 5 of <xref target="RFC8365"/>). </li>

    <li>BUM traffic using MP2MP tunnels. </li>
  </ul>

  <t>This document specifies procedures for BFD asynchronous mode. BFD
  demand mode is outside the scope of this specification except as it
  is used in <xref target="RFC8563"/>. The use of the BFD Echo
  function is outside the scope of this specification.</t>

</section>

<section>  <!-- 3. -->
  <name>Running BFD at the EVPN Network Layer</name>

    <t>The following considerations motivated the use of BFD at the
    network layer of the OAM model for EVPN (Section 2.3 of <xref
    target="RFC9062"/>):</t>

  <ul>
    <li>In addition to detecting network failures in an EVPN network,
    BFD sessions at the network layer can be used to monitor the
    successful setup, such as label programming, of MP2P and P2MP EVPN
    tunnels transporting Unicast and BUM traffic.  The scope of
    reachability detection covers the ingress and the egress EVPN PE
    (Provider Edge) nodes and the network connecting them. </li>

    <li>Monitoring a representative set of paths or a particular path
    among multiple paths available between two EVPN PE nodes could be
    done by exercising entropy mechanisms such as entropy labels, when
    they are used <xref target="RFC6790"/>, or VXLAN source port
    numbers <xref target="RFC7348"/>.  However, paths that cannot be
    realized by entropy variations cannot be monitored.  The fault
    monitoring requirements outlined by Section 3.1.1.1 of <xref
    target="RFC9062"/> are addressed by the mechanisms specified in
    this document. </li>
  </ul>

  <t>BFD sessions, as described herein, are requested when an EVPN
  route is established and the information necessary for the BFD
  session or sessions, as specified in <xref target="unicast"/> and
  <xref target="BUM"/>, is available. Data is not sent over the EVPN
  route until the BFD session or sessions are in the UP state.</t>

  <t>BFD testing between EVPN PE nodes does not guarantee that the
  EVPN service is functioning. This can be monitored at the service
  level, that is CE (Customer Edge) to CE (Section 2.2 of <xref
  target="RFC9062"/>) as shown in <xref target="OAMlayers"/>. For
  example, an egress EVPN PE could recognize EVPN labeling received
  and correctly process BFD packets but switch data to incorrect
  interfaces.  However, BFD testing in the EVPN Network Layer does
  provide additional confidence that data transported using those
  tunnels will reach the expected egress node.</t>

  <t>When BFD testing in the EVPN overlay fails, that can be used as
  an indication of a Loss-of-Connectivity defect in the EVPN underlay
  that would cause EVPN service failure; however, normally continuity
  checking at lower layers (the transport / link layers) SHOULD be
  done to detect underlay failures as this permits better localization
  of failures. Continuity testing at each layer SHOULD, if possible,
  be configured to detect failures more rapidly than at higher layers,
  for example with shorter BFD timers, for the following reasons:</t>

  <ul>
    <li>To facilitate repair, it is best to localize the area of a
    failure to as small an area as practical, which is best done by
    lower layers. If the failure is detected at a broader, higher
    layer area, while that detection can be reported, it may mask more
    localized lower layer failure detections.</li>
    
    <li>If lower layer failure detection is coupled with automatic
    lower layer path repair, premature detection at a higher layer may
    be a false detection in that the lower layer fault was in the
    process of being repaired.</li>
  </ul>
  
</section>

<section anchor="unicast">  <!-- 4. -->
  <name>Fault Detection for Unicast Traffic</name>

    <t>The mechanisms specified in BFD for MPLS LSPs <xref
    target="RFC5884"/> <xref target="RFC7726"/> and BFD for VXLAN
    <xref target="RFC8971"/> are, except as otherwise provided herein,
    applied to test loss of continuity for unicast EVPN traffic. This
    includes the following provision of <xref target="RFC5884"/>:</t>
    
    <blockquote>Note that once the BFD session for the MPLS LSP is UP,
    either end of the BFD session MUST NOT change the source IP
    address and the local discriminator values of the BFD Control
    packets it generates, unless it first brings down the
    session.</blockquote>

    <t>The MPLS control plane can be verified against the data plane
    as specified in <xref target="RFC8029"/>. When the discriminators
    required for de-multiplexing the BFD sessions are not otherwise
    available, for example by configuration, they can be advertised
    through BGP using the BFD Discriminator Attribute <xref
    target="RFC9026"/>.  Discriminators are needed for MPLS since the
    label stack does not contain enough information to identify the
    sender of the packet.</t>

    <t>The usage of different MPLS entropy labels <xref
    target="RFC6790"/> or different VXLAN source ports takes care of
    the requirement to monitor various paths of the multi-path
    provider network.  Each unique realizable path between the
    participating PE nodes MAY be monitored separately when such
    entropy is used.  At least one path of multi-path connectivity
    between two PE nodes MUST be tracked with BFD, but in that case
    the granularity of fault-detection will be coarser.</t>

    <t>To support unicast fault management with BFD packets sent to a
    PE node, that PE node MUST allocate or be configured with a BFD
    discriminator to be used as Your Discriminator (Section 4.1 of
    <xref target="RFC5880"/>) in the BFD messages to it. By default, a
    PE node advertises this discriminator with BGP using the BFD
    Discriminator Attribute <xref target="RFC9026"/> with BFD Mode
    TBD2 in an EVPN Ethernet Autodiscovery Route <xref
    target="rfc7432bis"/> or MAC/IP Advertisement Route as long as it
    advertises it in at least one route. It extracts its peer's
    discriminator from such an attribute. However, these
    discriminators MAY be exchanged out-of-band or through some other
    mechanism outside the scope of this document.</t>

    <t>Once a PE node knows a unicast route and discriminator for
    another PE node and is configured to do so, it endeavors to
    bring UP and maintain a BFD session to that other PE node. The BFD
    session is brought down if a PE node is no longer configured to
    maintain it or if a route and discriminator are no longer
    available.</t>

</section>

<section anchor="BUM">  <!-- 5. -->
  <name>Fault Detection for BUM Traffic</name>

    <t>Section 5.1 below discusses BUM traffic fault detection for P2P
    and MP2P tunnels using ingress replication and Section 5.2
    discusses such fault detection for P2MP tunnels. In both cases the
    following provision of <xref target="RFC5884"/> applies:</t>
    
    <blockquote>Note that once the BFD session for the MPLS LSP is UP,
    either end of the BFD session MUST NOT change the source IP
    address and the local discriminator values of the BFD Control
    packets it generates, unless it first brings down the
    session.</blockquote>

  <section anchor="IngressRep"> <!-- Section 5.1 -->
    <name>Ingress Replication</name>

      <t>Ingress replication (see Section 11 of <xref
      target="rfc7432bis"/>) uses separate P2P or MP2P tunnels for
      transporting BUM traffic from the ingress PE (head) to a set of
      one or more egress PEs (tails).  The fault detection mechanism
      specified by this document takes advantage of the fact that the
      head makes a unique copy for each tail.</t>

      <t>Another key aspect to be considered in EVPN is the
      advertisement of the Inclusive Multicast Ethernet Tag Route (see
      Section 7.3 of <xref target="rfc7432bis"/>).  The BUM traffic
      flows from a head node to a particular tail only after the head
      receives such an inclusive multicast route from the tail. This
      route contains the BUM EVPN MPLS label (downstream allocated)
      corresponding to the MP2P tunnel for MPLS encapsulation and
      contains the IP address of the PE originating the inclusive
      multicast route for use in VXLAN encapsulation. It also contains
      a BFD Discriminator Attribute <xref target="RFC9026"/> with BFD
      Mode TBD2 giving the BFD discriminator that will be used by the
      tail unless this information has been otherwise
      distributed. This is the P2P mode BFD Discriminator Attribute
      since a P2P BFD session is used in both the P2P and MP2P cases
      with ingress replication.</t>

      <t>There MAY exist multiple BFD sessions between a head PE and
      an individual tail due to (1) the usage of MPLS entropy labels
      <xref target="RFC6790"/> or VXLAN source port numbers for an
      inclusive multicast FEC and (2) due to multiple MP2P tunnels
      indicated by different tail labels for MPLS or different IP
      addresses for VXLAN encapsulation. If a PE node is configured to
      do so, once it knows a multicast route and discriminator for
      another PE mode it endeavors to bring UP and maintain a BFD
      session to that other PE node. The BFD session is brought down
      if a PE node is no longer configured to maintain it or if a
      route and discriminator are no longer available.</t>

  </section>
  <section anchor="P2MPtunnels">  <!-- 5.2 -->
    <name>P2MP Tunnels (Label Switched Multicast)</name>

      <t>Fault detection for BUM traffic distributed using a P2MP
      tunnel uses BFD Multipoint Active Tails <xref target="RFC8563"/>
      in one of the three methods providing head notification. Which
      method is used depends on the local configuration. Sections
      5.2.2 and 5.2.3 of <xref target="RFC8563"/> describe two of
      these methods ("Head Notification and Tail Solicitation with
      Multipoint Polling" and "Head Notification with Composite
      Polling").  The third method ("Head Notification without
      Polling") is touched on in Section 5.2.1 of <xref
      target="RFC8563"/> and fully specified in [ietf-mpls-p2mp-bfd].
      All these three modes assume the existence of a unicast
      return path from each tail to the head. In addition, Head
      Notification with Composite Polling assumes a head to tail
      unicast path disjoint from the path used by the P2MP tunnel.</t>

      <t>The BUM traffic flows from a head node to the tails after the
      head transmits an Inclusive Multicast Tag Route <xref
      target="rfc7432bis"/> if local configuration so directs. This
      route contains the BUM EVPN MPLS label (upstream allocated)
      corresponding to the P2MP tunnel for MPLS encapsulation. The
      route also includes a BFD Discriminator Attribute <xref
      target="RFC9026"/> with the BFD Mode set to 1 and a Source IP
      Address TLV, which gives the address associated with the
      MultiPoint Head of the P2MP session.  This BFD discriminator
      advertised by the head in the Inclusive Multicast route or
      otherwise configured at or communicated to a tail MUST be used
      in any reverse BFD control message as Your Discriminator so the
      head can determine the tail of which P2MP BFD session is
      responding. If a PE node is configured to do so, once a PE knows
      a P2MP multicast route and the needed discriminators, it brings
      UP and maintains a P2MP BFD active tails session to the tails.
      The BFD session is brought down if a PE node is no longer
      configured to maintain it or the multicast route and
      discriminators are no longer available.</t>

      <t>For MPLS encapsulation of the head to tails BFD, Label
      Switched Multicast is used. For VXLAN encapsulation, BFD is
      delivered to the tails through underlay multicast using an outer
      multicast IP address.</t>

  </section>

</section>

<section>  <!-- 6. -->
  <name>BFD Packet Encapsulation</name>

    <t>The following subsections describe the MPLS and VXLAN
    encapsulations of BFD for EVPN network layer fault management:</t>

    <section> <!-- 6.1 -->
      <name>MPLS Encapsulation</name>

    <t>This section describes use of the Generic Associated Channel
    Label (GAL, <xref target="RFC5586"/>) for BFD encapsulation in
    MPLS-based EVPN network layer fault management. Since the use of
    BFD specified in this document is encapsulated between PEs, it is
    treated as single hop and uses the single hop BFD port number
    <xref target="RFC5881"/>.</t>

    <section>
      <name>Unicast MPLS Encapsulation</name>

    <t>As shown in <xref target="MPLSunicast"/>, the packet contains
    the following labels in the order given: LSP label (transport),
    optionally an entropy label, the EVPN Unicast label, and then the
    Generic Associated Channel label with the G-ACh type set to TBD1.
    The G-ACh payload of the packet MUST contain the destination L2
    header (in overlay space) followed by the IP header that
    encapsulates the BFD packet.  The source MAC address of the inner
    packet can be used to validate the &lt;EVI, MAC&gt; in the
    receiving node.</t>

  <ul>
    <li>The destination MAC address MUST be the dedicated unicast MAC
    TBD4 (see Section 8) or the MAC address of the destination
    PE node.</li>
    <li>The destination IP address MUST be 127.0.0.1/32 for IPv4 or
    ::1/128 for IPv6 <xref target="RFC6890"/>.</li>
    <li>The destination UDP port number MUST be 3784 <xref
    target="RFC5881"/>. </li>
    <li>The source UDP port number MUST be in the range 49152 through
    65535. </li>
    <li>The discriminator values for BFD are obtained as discussed in
    Section 4. </li>
    <li>IPv4 TTL or IPv6 Hop Limit MUST be set to 255 according to
    <xref target="RFC5082"/>.</li>
  </ul>

<figure anchor="MPLSunicast">
  <name>MPLS Unicast Encapsulation</name>
  <artwork type="ascii-art">
    <![CDATA[
 <---------- 4 bytes ---------->
+-------------------------------+ --------
|          LSP Label            |        |
+-------------------------------+        |
:      entropy label indicator  :        |
+ (optional)                    +  MPLS Label Stack
:      entropy label            :        |
+-------------------------------+        |
|      EVPN Unicast label       |        |
+-------------------------------+        |
| Generic Assoc. Channel Label  |        |
+-------------------------------+ --------
|  ACH word, Type TBD1 no TLVs  |
+-------------------------------+ ----------  --------
|    Destination MAC Address    |          |         |
+               +---------------+          |         |
|   TBD3        |               |          |         |
+---------------+               +    L2 Header       |
|       Source MAC Address      |          |         |
+---------------+---------------+          |         |
|IP4/6 Ethertype|                          |         |
+---------------+---------------+  ---------         |
/                               /                    |
/...      IPv4/6 Header      .../          G-ACh Payload
/                               /                    |
+-------------------------------+                    |
|                               |                    |
+           UDP Header          +                    |
|                               |                    |
+-------------------------------+                    |
|                               |                    |
+       BFD Control Packet      +                    |
/                               /                    |
/...                         .../ --------------------
    ]]>
  </artwork>
</figure>

      </section>
      <section>
        <name>MPLS Ingress Replication</name>

    <t>When ingress replication is used for BUM traffic, a packet
    contains the following labels in the order given: LSP label
    (transport), optionally an entropy label, the BUM label, and the
    split horizon label <xref target="rfc7432bis"/> (where
    applicable).  The G-ACh type is set to TBD1.  The G-ACh payload of
    the packet is as described in Section 6.1.1 except that the
    destination MAC address, if not that of the destination PE node,
    is the dedicated multicast MAC TBD3.</t>

      </section>
      <section>
        <name>MPLS LSM (Label Switched Multicast, P2MP)</name>

    <t>When Label Switched Multicast is used for BUM traffic, the
    encapsulation is the same as in Section 6.1.2 for ingress
    replication except that the transport label identifies the P2MP
    tunnel, in effect the set of tail PEs, rather than identifying a
    single destination PE at the end of an MP2P tunnel.</t>

      </section>
      
  </section>
  
  <section>  <!-- 6.2 -->
    <name>VXLAN Encapsulation</name>

    <t>This section describes the use of the VXLAN <xref
    target="RFC7348"/> <xref target="RFC8365"/> for BFD encapsulation
    in VXLAN based EVPN fault management.</t>

    <section>  <!-- 6.2.1 -->
      <name>Unicast VXLAN Encapsulation</name>

    <t><xref target="VXLANunicast"/> below shows the unicast VXLAN
    encapsulation on the wire on an Ethernet link.  The outer and
    inner IP headers have a unicast source and destination IP address,
    both IPv4 or both IPv6 in each header, that are the addresses of
    the PE nodes that are the BFD message source and destination. The
    source port number MAY be varied as a source of entropy. If the
    BFD source has multiple IP addresses, whether multiple IPv4
    addresses, multiple IPv6 addresses, or a mixture thereof, entropy
    MAY be further obtained by using any of those addresses assuming
    the destination has a same version IP address and the source is
    prepared for responses directed to the IP address used.</t>

    <ul>
    <li>The outer destination UDP port number MUST be 4789 <xref
    target="RFC7348"/>.</li>
    <li>The inner destination UDP port number MUST be 3784 <xref
    target="RFC5881"/>. </li>
    <li>The outer and inner source UDP port numbers MUST each be in
    the range 49152 through 65535. </li>
    <li>The inner destination MAC number MUST be the MAC address of
    the destination PE or the dedicated unicast BFD over VXLAN
    address 00-00-5E-00-52-02 (see <xref target="RFC8971"/>). </li>
    </ul>

<figure anchor="VXLANunicast">
  <name>VXLAN Unicast Encapsulation</name>
  <artwork type="ascii-art">
    <![CDATA[
 <---------- 4 bytes ---------->
+-------------------------------+ ----------
|    Destination MAC Address    |          |
+               +---------------+          |
|               |               |          |
+---------------+               +  Outer L2 Header
|       Source MAC Address      |          |
+-------------------------------+          |
: VLAN Ethertype|     VLAN-ID   :<optional |
+---------------+---------------+          |
|IP4/6 Ethertype|                          |
+---------------+---------------+ ----------
/                               /
/...      IP4/6 Header       .../    
/                               /     
+-------------------------------+     
|                               |     
+           UDP Header          +     
|                               |     
+-------------------------------+     
|                               |     
+          VXLAN Header         +     
|                               |     
+-------------------------------+  ---
|    Destination MAC Address    |    |
+               +---------------+    |
|               |               |  Inner
+---------------+               +  L2 Header
|       Source MAC Address      |    |
+---------------+---------------+    |
| IP4 Ethertype |                    |
+---------------+---------------+  ---
/                               /
/...       IP4 Header        .../
/                               /
+-------------------------------+
|                               |
+           UDP Header          +
|                               |
+---------------+---------------+
|                               |
+       BFD Control Packet      +
|                               |
/...                         .../
    ]]>
  </artwork>
</figure>
    
    </section>
    <section>  <!-- 6.2.2 -->
      <name>VXLAN Ingress Replication</name>

    <t>When VXLAN encapsulated ingress replication is used, the BFD
    packet construction is as given in Section 6.2.1 except as
    follows:</t>

<ol>
<li>The destination IP address used by the BFD message source is that
advertised by the destination PE in its Inclusive Multicast EVPN route
for the MP2P tunnel in question; and</li>

<li>The Your BFD discriminator used is the one advertised by the BFD
destination using BGP as discussed in Section 5.1 for the MP2P
tunnel.</li>

<li>The destination MAC address, if not that of the destination PE
node, is the dedicated multicast BFD over VXLAN MAC address TBD5.</li>
</ol>

    </section>
    <section>  <!-- 6.2.3 -->
      <name>VXLAN P2MP</name>

    <t>When VXLAN head-to-tails (P2MP) is used, the encapsulation is
    as given in Section 6.2.2 except as follows:</t>

<ol>
  <li>The multicast destination IP address used is that corresponding
  to the VXLAN VNI.</li>

  <li>The Your BFD discriminator is the value distributed for this
  multicast fault management purpose as discussed in Section 5.2.</li>
</ol>

    </section>
  </section>
  
</section>

<section>
  <name>Scalability Considerations</name>

    <t>The mechanisms specified by this document could affect the
    packet load on the network and its elements especially when
    supporting configurations involving a large number of EVIs.  The
    option of decreasing or increasing BFD timer values can be used by
    an administrator or a network management entity to maintain the
    overhead incurred due to fault monitoring at an acceptable
    level.</t>

</section>

<section>
  <name>IANA Considerations</name>

<t>The following IANA Actions are requested.</t>

    <t>IANA is requested to assign a channel type from the "Pseudowire
    Associated Channel Types" registry in <xref target="RFC4385"/> as
    follows.</t>

<artwork type="ascii-art">
  <![CDATA[
Value   Description    Reference
-----   ------------   ------------
TBD1    BFD-EVPN OAM   [this document]
  ]]>
</artwork>


    <t>IANA is requested to assign a value from the IETF Review range
    in the BFD Mode sub-registry on the Border Gateway Protocol
    Parameters Registry web page as follows:</t>

<artwork type="ascii-art">
  <![CDATA[
 Value    Description      Reference
-----   ---------------   ---------------
TBD2    P2P BFD Session   [this document]
  ]]>
</artwork>


    <t>IANA is requested to assign parallel multicast and unicast MAC
    addresses under the IANA OUI [0x01005E900101 and 0x00005E900101
    suggested] as follows:</t>

<artwork type="ascii-art">
  <![CDATA[
 IANA Multicast 48-bit MAC Addresses
Address   Usage                  Reference
-------  ---------------------   ---------------
TBD3    EVPN Network Layer OAM   [this document]
          ]]>
</artwork>

<artwork type="ascii-art">
  <![CDATA[
 IANA Unicast 48-bit MAC Addresses
Address   Usage                  Reference
-------  ---------------------   ---------------
TBD4    EVPN Network Layer OAM   [this document]
  ]]>
</artwork>

    <t>IANA is requested to assign a multicast MAC address under the
    IANA OUI [ 00-00-0E-90-00-04 suggested] as follows:</t>
    
<artwork type="ascii-art">
  <![CDATA[
 IANA Multicast 48-bit MAC Addresses
Address   Usage                    Reference
-------  -----------------------   ---------------
TBD5    Multicast BFD over VXLAN   [this document]
          ]]>
</artwork>
    
  
</section>

<section>
  <name>Security Considerations</name>

    <t>Security considerations discussed in <xref target="RFC5880"/>,
    <xref target="RFC5883"/>, and <xref target="RFC8029"/> apply.</t>

    <t>MPLS security considerations <xref target="RFC5920"/> apply to
    BFD Control packets encapsulated in a MPLS label stack. When BFD
    Control packets are routed, the authentication considerations
    discussed in <xref target="RFC5883"/> should be followed.</t>

    <t>VXLAN BFD security considerations in <xref target="RFC8971"/>
    apply to BFD packets encapsulated in VXLAN.</t>

</section>

<section anchor="Acknowledgements">
  <name>Acknowledgements</name>
  
  <t>The authors place on record very special thanks to Alexander
  Vainshtein for his thoughtful comments and follow-up in shaping
  this document.</t>
  <t>The authors wish to thank the following for their comments and
  suggestions: Mach Chen, Jorge Rabadan, and Mohammed Boucadair</t>
  
</section>

</middle>


<!-- ____________________BACK_MATTER____________________ -->
<back>
<references>
  <name>Normative References</name>

  <reference anchor="ietf-mpls-p2mp-bfd"
             target="https://datatracker.ietf.org/doc/draft-ietf-mpls-p2mp-bfd/">
    <front>
      <title>BFD for Multipoint Networks over Point-to-Multi-Point
      MPLS LSP</title>
      <author fullname="Greg Mirsky" initials="G." surname="Mirsky">
        <organization>Ericsson</organization>
      </author>
      <author fullname="Gyan Mishra" initials="G." surname="Mishra">
        <organization>Verizon Inc.</organization>
      </author>
      <author fullname="Donald E. Eastlake 3rd" initials="D."
              surname="Eastlake">
        <organization>Futurewei Technologies</organization>
      </author>
      <date month="December" year="2022"/>
    </front>
  </reference>
  <reference anchor="rfc7432bis"
             target="https://datatracker.ietf.org/doc/draft-ietf-bess-rfc7432bis/">
    <front>
      <title>BGP MPLS-Based Ethernet VPN</title>
      <author fullname="Ali Sajassi" initials="A." surname="Sajassi">
        <organization>Cisco</organization>
      </author>
      <author fullname="Luc Andre Burdet" initials="LA."
              surname="Burdet">
        <organization>Cisco</organization>
      </author>
      <author fullname="John Drake" initials="J." surname="Drake">
        <organization>Juniper</organization>
      </author>
      <author fullname="Jorge Rabadan" initials="J." surname="Rabadan">
        <organization>Nokia</organization>
      </author>
      <date day="13" month="March" year="2023"/>
    </front>
  </reference>

<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.2119.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.4385.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5586.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5880.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5881.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5882.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5883.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5884.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.6790.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.6890.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.7726.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8029.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8174.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8365.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8562.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8563.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.9026.xml"/>

</references>

<references>
  <name>Informative References</name>

  <reference anchor="ietf-bmwg-evpntest"
           target="https://datatracker.ietf.org/doc/draft-ietf-bmwg-evpntest/">
    <front>
      <title>Benchmarking Methodology for EVPN and PBB-EVPN</title>
      <author fullname="Sudhin Jacob" initials="S." surname="Jacob">
        <organization>Independent</organization>
      </author>
      <author fullname="Kishore Tiruveedhula" initials="K."
              surname="Tiruveedhula"> 
        <organization>Juniper Networks</organization>
      </author>
      <date month="June" year="2021"/>
    </front>
  </reference>

<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5082.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.5920.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8317.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.7623.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.8971.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.9062.xml"/>
<xi:include
    href="https://www.rfc-editor.org/refs/bibxml/reference.RFC.7348.xml"/>

</references>
 <section anchor="Special_considerations" numbered="true">
   <name>Special considerations for EVPN BFD</name>
        <figure anchor="Figure-1_-evpn-pes-bfd-cons">
          <name>EVPN &amp; EVPN PE scenario for BFD</name>
          <artwork name="" type="" align="left" alt=""><![CDATA[

              EVPN PE1
            +------------+
            |(MAC-VRF1)  |                     EVPN PE3
            |  :   \     |    +---------+   +-----------+
            |  : (IP-VRF)|----|         |---|(MAC-VRF1) |   
     +------|  :   /     |    |         |   |  :   \    |
     |      |(MAC-VRF3)  |    |         |   |  : (IP-VRF|  +------+
     |      +------------+    |         |   |  :   /    |--| CE3  | 
  +--+--+                     |  MPLS/  |   |(MAC-VRF2) |  +------+
  | CE1 |      EVPN PE2       |  IP     |   +-----------+
  +--+--+   +------------+    |         |
     |      |(MAC-VRF1)  |    |         |
     |      |  :    \    |    |         |
     +------|  : (IP-VRF)|----|         |
            |  :    /    |    +---------+
            |(MAC-VRF3)  |
            +------------+
                          
]]></artwork>
        </figure>
  <t> The following are the topological aspects considered based on the above
   figure:</t>
  <ul>   
   <li> A group of EVI implementing VLAN-based service interface (for 
   simplicity) is instantiated in PE1, PE2 and PE3. </li>
   <li> PE1 and PE2 are attached to a multi-homed Ethernet Segment in 
   Single-Active redundancy mode. </li>
   <li> PE3 is not attached to this multi-Homed Ethernet Segment. </li>
   <li> Some of the EVI (say, EVI-1 and EVI-2) in this group elects PE1 as 
   the Designated Forwarder for this Multihomed Etherent Segment.</li>
   <li> At least one other EVI (say, EVI-3) selects PE2 as the DF for this 
   MH ES. </li>
   <li> An EVPN BFD session has been set up for monitoring unicast network 
   layer connectivity between a pair MAC-VRFs that locally EVI-1 in PE1 and 
   PE3 and between PE2 and PE3.</li>
  </ul> 
  <t> When due to mis-programming of the application label used by MAC-VRF
  that represents EVI-1 in PE1:</t>
  <ul>
  <li> The BFD session endpoint in PE1 stops receiving EVPN-BFD packets and 
  goes to DOWN state due to a local timeout.</li>
  <li> This BFD session endpoint indicates its DOWN state in the BFD Control 
  packets it sends, so that the BFD session endpoint goes DOWN also in PE3.
  It must be noted that the BFD session at PE3 goes down because PE1 signals
  the BFD Down State using Diagnostic code "Neighbor Signaled Session Down"
  <xref target ="RFC5880"/>.</li>
  <li> No other failures will be detected (e.g. in PE2). </li>
  </ul>
  <t>What actions can be taken at the individual PE Nodes are described below:</t>
  <ul>
  <li>There would be no actions required in PE2 since it is least impacted due
  to the failure. </li>
  <li> At PE3 the action could limited to reporting the fault to the operator. 
   using the Diagnostic Code received from PE1 <xref target="RFC5880"/></li>
  <li> <t>At PE1 there are various actions that could be considered:</t>
     <ul>
     <li><t>Notifying the operator about the fault is the basic operation
     that can be carried out in PE1 as well. This is mandatory.</t></li>
     <li><t>Additionally, there could be more optional actions considered. For
     example, if the fault at PE1 causes BFD failures greater than a certain
     number of sessions (minimum threshold) then the EVPN PE1 can decide to
     force a DF election by withdrawing the Ethernet Segment Route. How such
     procedures are done are outside the scope of this specification.</t></li>
     </ul></li>
  </ul>
 </section>


        


</back>
</rfc>